Loading product…
Converters
The CT Series consists of single-phase True RMS current transducers designed to convert the AC current signal from a current transformer into a proportional DC analog output.
ModelCT
The CT Series consists of single-phase True RMS current transducers designed to convert the AC current signal from a current transformer into a proportional DC analog output. The series provides current measurement for industrial monitoring and control applications, with multiple analog output configurations and AC or DC auxiliary supply options.
Our sales engineers work directly with panel builders and procurement teams to specify the right product, confirm lead times, and coordinate international shipping.
| Auxiliary Supply — DC Model | 24 V DC (9–34 V DC) |
|---|---|
| Auxiliary Supply — AC Model | 220 V AC (85–280 V AC) |
| Galvanic Isolation — DC Model | Not isolated |
| Galvanic Isolation — AC Model | 1.5 kV isolation, 3.0 kV withstand |
| Max. Power Consumption — DC Model | 1 W (35 mA) at 24 V DC |
| Max. Power Consumption — AC Model | 2 W (20 mA) at 115 V AC / 3 W (15 mA) at 230 V AC |
| Measurement Method | True RMS |
|---|---|
| Input Current Range | 0–1 A AC / 0–5 A AC |
| Continuous Overload Current | 10 A AC |
| Input Signal Frequency | 40–100 Hz |
| Sampling Frequency | 31 kHz (typical) |
| Conversion Accuracy | Max. 1.0% error at nominal current, 25°C |
| Response Time | 100 ms (typical) |
| Analog Current Output | 4–20 mA / 0–20 mA |
|---|---|
| Analog Voltage Output | 0–5 V / 0–10 V / 1–5 V / 2–10 V |
| Max. Output Load — Current Output | 700 Ω at 24 V DC supply |
| Min. Output Load — Voltage Output | 10 Ω |
| Output Load Error | Max. 5% error |
| Operating Temperature | -10°C to +60°C |
|---|
| Mounting | DIN rail |
|---|