Loading product…
Power Quality and Energy
The EA-C5 is an advanced three-phase panel-mounted energy analyzer designed for comprehensive measurement, energy monitoring and power quality monitoring in low- and medium-voltage electrical systems.
ModelEA-C5
The EA-C5 is an advanced three-phase panel-mounted energy analyzer designed for comprehensive measurement, energy monitoring and power quality monitoring in low- and medium-voltage electrical systems. It measures voltage, current, frequency, active, reactive and apparent power, power factor, energy, and harmonic components up to the 55th harmonic.
Our sales engineers work directly with panel builders and procurement teams to specify the right product, confirm lead times, and coordinate international shipping.
| Voltage Measurement | Phase-to-phase, Phase-to-neutral |
|---|---|
| Current Measurement | I1, I2, I3, ΣI |
| Frequency | F1, F2, F3 |
| Active Power | P1, P2, P3, ΣP |
| Reactive Power | Q1, Q2, Q3, ΣQ |
| Apparent Power | S1, S2, S3, ΣS |
| Power Factor | True PF, cos φ of each phase |
| Active Energy | ΣkWh (Import & Export) |
| Reactive Energy | ΣkVArh (Inductive & Capacitive) |
| Total Harmonic Distortion | THD-V, THD-I |
| Voltage Harmonics | Up to 55th harmonic (L-N and L-L) |
| Current Harmonics | Up to 55th harmonic |
| Voltage / Current Accuracy | ±0.2% |
| Active Energy Accuracy | ±0.5% |
| Reactive Energy Accuracy | ±1% |
| Operating Voltage | 85–240 V AC |
|---|---|
| Operating Frequency | 50/60 Hz |
| Operating Power | <10 VA |
| Input Voltage (L-N) | 1–330 V AC |
| Voltage Measuring Range | 1 V–600 kV |
| Input Current | 1 mA–5.5 A |
| Current Measuring Range | 1 mA–50,000 A |
| Current Transformer Ratio | 1–5000 |
| Voltage Transformer Ratio | 1.0–9999 |
| Supported Connection |
| Communication | RS485 Modbus RTU |
|---|---|
| Relay Output | 2 Adjustable Relay Outputs |
| Relay Contact Rating | 2 A / 250 V AC (Resistive Load) |
| Digital Input | 9–24 V DC |
| Event Logs | High/low voltage, power interruption, voltage/current imbalances, high current, THD-V and THD-I limits |
| Real-Time Clock | Date and time can be set |
| Memory | Energy values, demand records and event logs can be deleted |
| Password Protection | Menu is password protected |
| Display | 71.5 × 61.5 mm Custom Design Glass LCD |
|---|---|
| Panel Size | 96 × 96 mm |
| Panel Cut-Out | 91 × 91 mm |
| Cable Cross-Section | 1.5 mm² |
| Protection Degree | IP41 Front Panel / IP20 Body |
| Operating Temperature | -20°C to +55°C |
|---|
| 3P4W |